The VGU - 200 water heating unit is designed to heat service water at least + 90 0 С, with an hourly gas consumption of 80 - 90 m З / hour.
Technical data:
· Indicator name - Norm;
· Rated heating capacity, 0.63 -1.26 MW;
· The volume of the working tank (body) - 200m 3 ;
· Hourly water consumption, m 3 / hour - 24 (80 ... 90 with a decrease in the heating temperature), Excessive water pressure in the body, MPa (kgf / cm 2 ) - 0.04 (0.4);
· Fuel type - associated and natural gas with a calorific value - 35-60 MJ / m 3 , Maximum water temperature at the outlet of the unit, 95 АС ;
· The minimum water temperature before heating starts, 16 АС ;
· Minimum flue gas temperature 220 АС ;
· The volume of the combustion chamber - 15.9 m 3 ;
· Nominal vacuum at the end of the furnace is not less than - 300Pa (30kgf / m);
· Installation weight - 44.2 tons;
· The mass of the metal parts of the installation is not more than - 45 tons:
o overall dimensions, m;
o length - 28;
o width - 3,5;
o height 3,7;
o height without chimney - 4,5;
o duration of the working cycle, h,- 13;
o coefficient of performance (efficiency),%, - 74.